π Abaqus U1 U2 U3 Meaning
To edit an existing base motion boundary condition using menus or managers, see Editing step-dependent objects. In the Basic tab, select the Degree-of-freedom to specify the direction for which the base motion is being defined. This direction is always a global direction: U1, U2, U3, UR1, UR2, or UR3.
So if you define a cylindrical coordinate system, at a particular point U2 = tangential displacement, UR3 = rotation about local "z" axis (axis that runs throught the point of interest and is parallel to the cylindrical coordinate system axis).
XASYMM Antisymmetry about a plane with X = constant (U2 = U3 = UR1 = 0;ABAQUS/Standard only). YASYMM Antisymmetry about a plane with Y = constant (U1 = U3 = UR2 = 0;ABAQUS/Standard only). ZASYMM Antisymmetry about a plane with Z = constant (U1 = U2 = UR3 = 0;ABAQUS/Standard only). PINNED Pinned (U1 = U2 = U3 = 0).
If you model the part with generalized plane strain elements, you must use the Keywords Editor to apply boundary conditions on the active degrees of freedom (U3, UR1, and UR2) at the reference node of these elements (see Adding unsupported keywords to your Abaqus/CAE model).
YASYMM: Antisymmetry about a plane with Y = constant (U1 = U3 = UR2 = 0;ABAQUS/Standard only). ZASYMM: Antisymmetry about a plane with Z = constant (U1 = U2 = UR3 = 0;ABAQUS/Standard only). PINNED: Pinned (U1 = U2 = U3 = 0). ENCASTRE: Fully built-in (U1 = U2 = U3 = UR1 = UR2 = UR3 = 0).
What is the unit of U3 in Abaqus in the result. degree or radian? I performed quasi-static analysis on gears in ABAQUS. After analysis, I extracted the U3 parameter to measure the gear
The fundamental units in the SI system are length in meters (m), mass in kilograms (kg), time in seconds (s), temperature in degrees kelvin (K), and electric current in amperes (A). The units of secondary or derived quantities are based on these fundamental units. An example of a derived unit is the unit of force.
U1, U2, U3 *NODE OUTPUT, NSET=FNDNbase Output to .obd file RF1, RF2, RF3, RM1, RM2, RM3 *ELEMENT OUTPUT, ELSET=ELopt1 SF1, SF2, SF3, SM1, SM2, SM3 ΓCan be post-processed in CAE. Applying Gravity Load 30 28 Change to ABAQUS working directory firstChange to ABAQUS working directory first.
Abaqus/CAE Usage Load module: Create Boundary Condition: Step: Initial Using the direct format You can choose to enter the degrees of freedom to be constrained directly. Input File Usage Either a single degree of freedom or the first and last of a range of degrees of freedom can be specified.
Antisymmetry about a plane with Y = constant (U1 = U3 = UR2 = 0;Abaqus/Standard only). ZASYMM: Antisymmetry about a plane with Z = constant (U1 = U2 = UR3 = 0;Abaqus/Standard only). PINNED: Pinned (U1 = U2 = U3 = 0). ENCASTRE: Fully built-in (U1 = U2 = U3 = UR1 = UR2 = UR3 = 0).
β’ In the boundary condition module constrain U1, U2, U3 at the entire bottom of the part to zero. Apply a displacement of U1= -0.00254 on the other end of the part. β’ Create a job and submit and run it (it will take some time to complete, as the mesh has 30000 quadratic elements).
biLK6cs.